How to deal with the failure of high and low temperature test chambers

Basic troubleshooting methods for high and low temperature test chambers:

1. High and low temperature test chambers In the high temperature test, if the temperature change does not reach the test temperature value, the electrical system can be inspected and the faults can be eliminated one by one. If the temperature rises very slowly, it is necessary to check the air circulation system to see if the regulating baffle of the wind cycle is normal. On the contrary, check whether the motor of the wind cycle is running normally. If the temperature is too high, you need to set the PID setting parameters. If the temperature rises directly and the temperature is over-protected, then the controller fails and the control instrument must be replaced.

When the high and low temperature test chamber suddenly fails during the test operation, the corresponding fault display prompt appears on the control instrument and an audible alarm prompt is displayed. The operator can quickly check which type of fault is involved in the troubleshooting chapter of the operation of the equipment, and then ask the professional to quickly eliminate the fault to ensure the normal operation of the test. Other environmental testing equipment will have other phenomena in use, and it will be specific phenomena, specific analysis and elimination. The environmental test equipment should be regularly maintained, the condenser of the refrigeration system should be cleaned regularly, the moving parts should be lubricated according to the instructions, the electrical control system should be regularly maintained and checked, etc. These work are essential. 3. High and low temperature test chambers are low temperature. If you can't reach the test index, then you should observe the change of temperature. It is the temperature drop is very slow, or the temperature has a rising trend after the temperature reaches a certain value. The former should check whether the studio is baked before the low temperature test. Dry, make the studio dry and then put the test sample into the work room and then test it. If the test sample in the work room is placed too much, the wind in the workroom cannot be fully circulated. After eliminating the above reasons, it is necessary to consider whether It is a fault in the refrigeration system, so it is necessary to ask the professional of the manufacturer for maintenance. The latter phenomenon is caused by the poor use of the equipment. The ambient temperature at which the equipment is placed and the location where it is placed (the distance between the rear of the cabinet and the wall) must meet the requirements (as specified in the operating instructions for the equipment).

Fourth, the high and low temperature test chamber in the damp heat test, the actual humidity will reach 100% or the actual humidity and the target humidity are very different, the value is much lower, the former phenomenon: may be caused by the dry gauze on the wet bulb sensor, then It is necessary to check whether there is water shortage in the water tank of the wet bulb sensor. The water level in the water tank is automatically controlled by a water level controller. Check whether the water supply system of the water level controller is normal and the water level controller works normally. Another possibility is that the wet gauze is hardened due to the long use time or the purity of the water supply, so that the gauze becomes hard and the gauze can not absorb moisture and is dry. The above phenomenon can be eliminated by replacing or cleaning the gauze. The latter phenomenon is mainly because the humidification system does not work. Check the water supply system of the humidification system, whether there is a certain amount of water in the water supply system, whether the water level control of the humidification boiler water level is normal, and whether the water level in the humidification boiler is normal. If everything above is normal, then check the electrical control system, which should be repaired by professional maintenance personnel.

Heat Meters


Heat meters are one kind of meters measuring the heat consumption. In order to save the energy and decrease the environment pollution, the heat meters are more and more popular for the modern buildings. Heat meters can realize centralized heating supply. Now with the rapid technology development, the heat meters also experience a fast way of growing up. Now the government of the world starts to pay much attention to the building remolding and new buildings heat meter installation. As the new type of energy calculation, the heat meters have the advantages of higher accuracy, energy saving and easy installation.

From the functions of the different types of heat meters, there are mechanical heat meters, digital heat meter,Ultrasonic Heat Meters, M-bus Heat Meters and also wireless heat meters. Our company, Berggruen Technology Co.,Ltd never stops the steps for further higher technology research and development. We are devoted to study the new technology in the world to make better quality heat meters.



Heat Meters,Mechanical Heat Meters,Ultrasonic Heat Meters,M-Bus Heat Meter,Digital Heat Meter

Berggruen Technology Co.,Ltd , https://www.meter-technology.com